Until recently I've been pleased with the Summit thermoswitch I put on the Miata a couple years ago. However recently it started not shutting the cooling fan off once turned on. Research indicates this is a common problem with Summits 200 deg-on, 185 deg-off switch.

In my search for a more robust switch I found the SW510 switch, an original equipment switch for 80s model 4 cyl. Mustangs. The problem is with it installed the fan runs all the time. It appears this is a normal closed switch where the Summit was a normal open switch.

If the above is correct, can I fix the problem with a change in wiring? I'm currently running a four post, 50 amp relay with a 180 degree thermostat.

Thanks in advance. RR
Reply
Old May 5, 2015 | 12:43 PM
  #2  
tbone heller's Avatar
V8 Miata Zealot
 
Joined: Mar 2010
Posts: 1,220
Likes: 51
From: Canton, Georgia
Default

Currently I am using the Mazda fan switch to trigger my Ford fan relay. I also have a dash-mounted toggle switch that can activate the fans as well. I have found that turning the fans on BEFORE the coolant temps rise in traffic to be a good thing.
Reply
Old May 5, 2015 | 01:59 PM
  #3  
MRM331's Avatar
Administrator
 
Joined: Nov 2009
Posts: 1,120
Likes: 38
From: Allentown, PA
Default

I've used a Hayden thermocoupler kit on a few builds. The entire kit is around $25 and includes a relay and fuse. If the fixed on/off on that kit is not what you want they also have a whole range of adjustable ones that all cost less than a new Miata thermoswitch.

http://www.summitracing.com/search/b...n%20Automotive

I have mine triggered using my MS2 to come on at 210 and off at 195 which keeps street temps right around 190-195 and track temps around 200-210. If I was not using Evan's waterless coolant (higher boiling point than water) I'd set it about 10 degrees lower.

-Jason
Reply
Old May 6, 2015 | 07:26 AM
  #4  
5.0MX5's Avatar
Thread Starter
V8 Miata Participant
 
Joined: Jan 2010
Posts: 290
Likes: 12
Default

Tom and Jason, thanks for the comments. I'll likely use the Summit kit Jason linked if I can't make the newly installed replacement switch work. I do like the idea of factory switches since I'd expect longer life than typically found in cheap devices designed for and sold to the hot rod market.

Like tbone, I have a manual switch so the car isn't grounded. I just turn the fan on in low speed situations and when stopped, off if above 30 mph.
Reply
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
stng_96
V8 Miata Engines
3
May 27, 2015 11:53 AM
Gunpilot
Ford V8 Discussion
6
Jul 24, 2014 07:28 PM
JLOracing
General Motors V8 Discussion
6
Nov 14, 2012 10:41 AM
ls1miata
V8 Miata Wiring, Electrical, and ECUs
5
Sep 21, 2010 03:04 PM

Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 

Thread Tools
Search this Thread
Rate This Thread
Rate This Thread:
You have already rated this thread Rating: Thread Rating: 0 votes,  average.


All times are GMT -5. The time now is 08:09 AM.